Page 1 - Raritan Hold-N-Treat for Purasan EX L519v0919
P. 1

PURASAN EX Hold n’ Treat
                                                   ®

                       OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS
                         (Models PST*EX  [*specify 12,24] Manufactured after December 2013)


                     THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
                              FOLLOWED DURING BOTH INSTALLATION AND OPERATION
               WARNING:  Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product.
                          Equipment damage, injury to personnel or death could result from improper installation.  Raritan Engineering
                          Company, Inc. accepts no responsibility or liability for damage to equipment, or injury or death to personnel
                          that may result from improper installation or operation of this product.
                WARNING:  HAZARD OF SHOCK AND FIRE
                          Always use recommended fuse or circuit breaker and wire size.

                WARNING:  HAZARD OF FLOODING - When leaving the boat unattended always be sure seacocks are closed.  Any
                          installation made below waterline should have double hose clamps securing lines.  The halogen disinfectant
                          is corrosive to aluminum, copper and steel.  The plumbing system must not include any aluminum,
                          copper or steel fittings, piping or holding tanks.

                  IMPORTANT SAFETY INSTRUCTIONS FOR HANDLING PURASAN  TABLETS AND SOLUTION
                                                                                 ®
            WARNING:   PURASAN  EX disinfecting tablets are a strong oxidizing agent and highly corrosive. Use or contact
                                 ®
                       with oil, acids, petroleum products, reducing agents or other chlorine compounds such as swimming
                       pool tablets, is extremely dangerous

               WARNING:  Fire or explosion could result. Improper use of this tablet may cause personal injury or property damage.
                       Tablets may be fatal if swallowed and tablet dust is irritating to the eyes, nose and throat. Keep out of
                       reach of children and do not allow tablets or solution of tablets to contact skin, eyes or clothing. Handle
                       and store tablets as per instructions provided with packaging. Contact Raritan if handling instructions
                       are missing. Store only in sealed original container in well-ventilated area. Read tablet container label
                       carefully prior to use. It is unsafe and violation of Federal law to use tablets in a manner inconsistent
                       with its labeling.

             The PURASAN EX is a U. S. Coast Guard Certified Type I Marine Sanitation Device for use on unin-
                            ®
             spected vessels 65 feet and under. It must be operated within navigable waters inside the three mile limit
             that are not declared Federal No Discharge Zones (NDZ) by the U.S. Environmental Protection Agency
             (EPA).  Other countries - check with local authorities.
             The PURASAN EX is designed for recreational use and accommodates most marine toilets.  The
                            ®
             PURASAN EX is available in 12 or 24 VDC.
                        ®
             DESCRIPTION:
             Each time the transfer pump cycles an equal amount of previously treated waste is discharged. The pump-
             ing action of the transfer pump moves the waste through the PURASAN EX and out.
                                                                                  ®
             Water is diverted to the Tablet Dispenser during the treatment cycle, creating a halogen solution during hold
             time. After the hold time, the Drain Manifold and Air Pump turn on and the solution drains into the Treat-
             ment Unit.The first chamber macerates to reduce particle size and uniformly mix the waste with injected
             halogen solution. The second chamber mixes to ensure uniform treatment of its contents.
            The Hold n’ Treat is designed to integrate both a Type I and Type III MSD (Marine Sanitation Device) to
            provide the user with a system that will be legal in all areas.
            All waste is stored in a holding tank and the treatment mode will determine how the waste is processed.
            This system eliminates the need for pump-out stations in most areas.

           L519 _0919jlc                                      1
   1   2   3   4   5   6