Page 1 - Raritan Smart Toilet Control Bluetooth Owners Manual L381v0420
P. 1
FLUSH CONTROL
Installation, Operation and Maintenance Instructions
Part# STCBL
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install
this product. Equipment damage, injury to personnel or death could result from improper instal-
lation. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to
equipment, injury or death to personnel that may result from improper installation or operation
of this product.
WARNING: HAZARD OF SHOCK OR FIRE
Always use recommended fuse, circuit breaker and wire size.
Motors used with this product are “Ignition Protected”. They are not however, explosion-
proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.
DO NOT run continuously for more than 30 seconds.
Description:
Panel Flush Control is a controller for flushing toilet to
3 optimize water use without compromising the quality
4 [121]
4 of flush.
Control consists of a controller and panel (batteries
included).
STCBL is designed to automatically start a
RARITAN
flushing cycle if NORMAL FLUSH
1
3 [82] or WATER SAVER buttons are pressed.
RARITAN
4 RARITAN
FLUSH WATER ONLY button brings inlet water to
the bowl when pressed and EMPTY ONLY
FLUSH
button evacuates the bowl.
FLUSH
DEPTH 1” [25] Flush timing is preset from the factory for
Sequential Flushing. Flush settings can be changed
by downloading the Raritan App to your Smart-
Control box phone. See “Changing Flush Settings Instructions”
3
6 on page 8.
16
The Flush Control has optional Holding Tank
[157]
Full indicators available (see page 7). When
Holding Tank Full is lit, Normal Flush and
Flush Control Water Saver button are disabled. Water Only and
STCBL
7 RARITAN Disconnect power before opening cover Empty Only button continue to function.
4
16 www.raritaneng.com
[113] Control is reverse polarity protected. In case of
reverse polarity motors and solenoid will activate as
soon as power is connected. After reverse polarity
is corrected (within 10 minutes), unit will work as
normal.
5
DEPTH 1 [41]
8
L381 0420 jlc 1