Page 1 - Raritan Smart Toilet Control Bluetooth Owners Manual L381v0420
P. 1

FLUSH CONTROL


                     Installation, Operation and Maintenance Instructions
                                                    Part# STCBL



                    THE  FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
                             FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
             WARNING:       Raritan Engineering Company, Inc. recommends that a qualified person or electrician install
                            this product.  Equipment damage, injury to personnel or death could result from improper instal-
                            lation.  Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to
                            equipment, injury or death to personnel that may result from improper installation or operation
                            of this product.
             WARNING:       HAZARD OF SHOCK OR FIRE
                            Always use recommended fuse, circuit breaker and wire size.
                            Motors  used  with  this  product  are  “Ignition  Protected”.  They  are  not  however,  explosion-
                            proof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.
                            DO NOT run continuously for more than 30 seconds.


                                                              Description:
                                Panel                                 Flush Control is a controller for flushing toilet to

                                   3                          optimize water use without compromising the quality
                                  4  [121]
                                   4                          of flush.
                                                              Control consists of a controller and panel (batteries
                                                              included).
                                                              STCBL is designed to automatically start a
                                    RARITAN
                                                              flushing cycle if  NORMAL FLUSH
            1
           3  [82]                                            or  WATER SAVER        buttons are pressed.
                                                                                          RARITAN
            4                                                             RARITAN
                                FLUSH                         WATER ONLY         button brings  inlet water to
                                                              the bowl when pressed and EMPTY ONLY
                                                                                       FLUSH
                                                              button  evacuates the bowl.
                                                                       FLUSH

                              DEPTH  1” [25]                  Flush timing is preset from the factory for
                                                              Sequential Flushing. Flush settings can be changed
                                                              by downloading the Raritan App to your Smart-
                              Control box                     phone. See “Changing Flush Settings Instructions”
                                    3
                                  6                           on page 8.
                                   16
                                                              The     Flush Control has optional Holding Tank
                                  [157]
                                                              Full      indicators available (see page 7). When
                                                              Holding Tank Full       is lit, Normal Flush and
                                Flush Control                 Water Saver button are disabled. Water Only and
                                  STCBL
               7         RARITAN     Disconnect power before opening cover  Empty Only button continue to function.
              4
               16        www.raritaneng.com
               [113]                                          Control is reverse polarity protected. In case of
                                                              reverse polarity motors and solenoid will activate as
                                                              soon as power is connected. After reverse polarity
                                                              is corrected (within 10 minutes), unit will work as
                                                              normal.
                                    5
                               DEPTH  1 [41]
                                    8
         L381 0420 jlc                                          1
   1   2   3   4   5   6