Page 11 - Raritan Managerm Owners Manual USA L350v0908
P. 11
• Unit should be cross-vented to port and starboard.
• Do not vent into a confined space onboard.
• Vents must not have sags, loops or obstructions where
water can collect, restricting air flow.
• Vent lines should be sloped to allow condensation to ^ ^
drain from vents into tanks.
SLOPED INSTALLATION
• Although a properly operating system should not have
odors, do not locate vent through-hull fittings near galley,
sleeping or high use areas.
Secondary tank should be vented separately from
primary tank to prevent primary tank from chlorine
contamination.
Installing Aerator Pump
CONNECT TUBING FROM AERA-
WARNING: Not certified for use in an explo- TOR PUMP HERE AGITATOR VALVE
sive environment.
DIFFUSER VALVE
• Install Aerator Pump above tank in a secure area.
• Install in a well ventilated area. Aerator Pump must
have fresh air available.
• Install within 6 feet (2 meters) of fitting on primary
tank.
• Receptacle to plug in pump must be GFCI (ground
fault circuit interrupter) protected with 5 Amp circuit
breaker.
1. Connect 1/2” hose to Aerator Pump. AERATOR PUMP
2. Connect 1/2” hose to fitting on primary tank.
3. Make sure diffuser and agitator valves are in correct
position(s).
4. Plug aeration pump into GFCI receptacle. If hard- 6 FT. (2 m.) RUN
OF TUBING
wiring, be sure to follow all appropriate regulations
PORT and codes.
Proceed to Start Up Section of Manual
L350 0908vkm 11
.