Page 11 - Raritan Managerm Owners Manual USA L350v0908
P. 11

•  Unit should be cross-vented to port and starboard.


        •  Do not vent into a confined space onboard.

        •  Vents must not have sags, loops or obstructions where
        water can collect, restricting air flow.


        •  Vent lines should be sloped to allow condensation to            ^  ^
        drain from vents into tanks.
                                                                         SLOPED                               INSTALLATION
        •  Although a properly operating system should not have
        odors, do not locate vent through-hull fittings near galley,
        sleeping or high use areas.

        Secondary tank should be vented separately from
        primary tank to prevent primary tank from chlorine
        contamination.



        Installing Aerator Pump

                                                                        CONNECT TUBING FROM AERA-
               WARNING:  Not certified for use in an explo-                   TOR PUMP HERE   AGITATOR VALVE
        sive environment.
                                                                    DIFFUSER VALVE
        •  Install Aerator Pump above tank in a secure area.


        •  Install in a well ventilated area.  Aerator Pump must
            have fresh air available.

        •  Install within 6 feet (2 meters) of fitting on primary
            tank.


        •  Receptacle to plug in pump must be GFCI (ground
            fault circuit interrupter) protected with 5 Amp circuit
            breaker.


        1.  Connect 1/2” hose to Aerator Pump.                              AERATOR PUMP
        2.  Connect 1/2” hose to fitting on primary tank.
        3.  Make sure diffuser and agitator valves are in correct
             position(s).
        4.  Plug aeration pump into GFCI receptacle.  If hard-                                   6 FT. (2 m.) RUN
                                                                                                  OF TUBING
             wiring, be sure to follow all appropriate regulations
 PORT        and codes.

        Proceed to Start Up Section of Manual










        L350   0908vkm                                       11
        .