Page 10 - Raritan Hold-N-Treat Electroscan EST System L372v0717
P. 10

CALIBRATION
          TROUBLE SHOOTING
              Sensor is factory calibrated for the hold and   WINTERIZATION
              treat system tank.                              Caution: Do not energize Eectro Scan or Lectra
              Use following instructions only if factory cali-  San with glycol in the tank to avoid sever overheat-
              bration does not work or you need to do the     ing or explosion.
              calibration for other reasons.                  Tank: Pump out holding tank using pump out fitting
              Pressure switches are factory set to operate on   Electro Scan: see Electro Scan manual for winter-
              low and high level.                             ization instructions.
              To recalibrate, empty out tank by:
              1.   Powering macerator pump with positive
                  and negative directly  or
                  To run macerator/tranfer pump only
                  1 Set the mode to MANUAL
                  2 Press start stop button to start sytem
                             with pump
                  3 After macerator  pump stops, prees start/                           HIGH LEVEL SWITCH
                             stop again to to stop system
                  4  Repeat steps  2 &3 several times to
                             empty tank
              2.   Run the system in MANUAL  mode.
                    When tank is empty start using system and
                  system will auto calibrate.





             TROUBLE SHOOTING:


            **WARNING** TANK  NEAR  FULL

                                                                                         LOW LEVEL SWITCH
              * If tank is not full:
                     1. Check wiring , level switch
                     wires may have been swiched
                     2. Check high level switch with a
                     meter, switch must be open if tank
                     is not full
              * If system is in AUTOMATIC mode:

                     1. Check macerator pump
                     2. Check low level switch
              * If system is in NO DISCHARGE  or
                     MANUAL mode:
                     1. Pump out holding tank
                     2. Switch to AUTOMATIC mode
                     if treated discharge is allowed
              FOR ALL OTHER WARNINGS AND
              ERRORS:
                     See electro scan manual.