PLUMBING:

             The Tank Assembly has four 1 1/2" NPT female
             ports available for connecting  toilet(s) and vent
             line(s). Tank Assembly also has a port dedicated
             for Pump-Out Plumbing. Unused port(s) MUST
             be plugged.


             1.    Connect discharge of toilet to one port on tank                                                INSTALLATION
             2.    Other ports are for a second toilet, vent line
                  and pump-out fitting. (See Installing Vents                        1 1/2" NPT Ports
                  below)                                          Macerator
             3.     Plug unused ports.                               Pump
             4.    Connect pump-out plumbing to port Pump-
                  Out Port.                                      Treatment
             5.    Determine position and glue Discharge Elbow     Tank
                  to top of Treatment Tank using PVC cement.
                  (refer to the Electro Scan manual)
             6.    An adapter fitting is provided for connecting
                  Discharge Elbow to hose. Connect hose from
                  Discharge fitting to thru hull fitting, thru
                  vented loop if needed.                                                            Mounting


             Installing Vents                                   Glue Discharge
             IMPORTANT                                                                   Pump-Out Port
             •    Do not vent into a confined space onboard.    Elbow Here
             •    Vents must not have sags, loops or obstructions
                  where water can collect, restricting air flow.
             •    Vent lines should be sloped to allow condensa-
                  tion to drain from vents into tanks.
             •    Do not locate vent through-hull fittings near
                  galley, sleeping or high use areas.


             INSTALLING SALT FEED SYSTEM:
               Fresh water toilets requires a salt feed
               systems with the pump. Raritan Part number
               32-3005 (12v) or 33-3005 (24v). See detail
               instructions enclosed in salt feed system.