PLUMBING:
The Tank Assembly has four 1 1/2" NPT female
ports available for connecting toilet(s) and vent
line(s). Tank Assembly also has a port dedicated
for Pump-Out Plumbing. Unused port(s) MUST
be plugged.
1. Connect discharge of toilet to one port on tank INSTALLATION
2. Other ports are for a second toilet, vent line
and pump-out fitting. (See Installing Vents 1 1/2" NPT Ports
below) Macerator
3. Plug unused ports. Pump
4. Connect pump-out plumbing to port Pump-
Out Port. Treatment
5. Determine position and glue Discharge Elbow Tank
to top of Treatment Tank using PVC cement.
(refer to the Electro Scan manual)
6. An adapter fitting is provided for connecting
Discharge Elbow to hose. Connect hose from
Discharge fitting to thru hull fitting, thru
vented loop if needed. Mounting
Installing Vents Glue Discharge
IMPORTANT Pump-Out Port
• Do not vent into a confined space onboard. Elbow Here
• Vents must not have sags, loops or obstructions
where water can collect, restricting air flow.
• Vent lines should be sloped to allow condensa-
tion to drain from vents into tanks.
• Do not locate vent through-hull fittings near
galley, sleeping or high use areas.
INSTALLING SALT FEED SYSTEM:
Fresh water toilets requires a salt feed
systems with the pump. Raritan Part number
32-3005 (12v) or 33-3005 (24v). See detail
instructions enclosed in salt feed system.
L372 0717jlc 7