NO DISCHARGE MODE:                                                   ****STANDBY****   ****STANDBY****
              Treatment is on hold and treatment inactive to prevent            MODE AUTOMATICMODE  NO DISCHARGE
              any discharge.
            Display indicates :
            •  Standby mode no discharge                                                                          OPERATION


            MANUAL MODE:
              Single treatment starts when start/stop button is pressed.        ****STANDBY****
                                                                                   ****STANDBY****
              This mode can be used to completely drain the tank                MODE AUTOMATIC    MODE MANUAL
              ( even below low level ) before entering a no discharge
              area or for maintenece purposes.
              Display indicates one of the following status
            •  Pretreatment or treatment cycle
            •  Standby (press) Start to empty
            ALL MODES:
            Display shows                                                       ****STANDBY****   ****STANDBY****
            **Warning***  Tank near full                                       MODE AUTOMATIC   START TO EMPTY
            If tank level is higher than high level switch. System status
              panel red LED will be blinking
            OPTIONAL  ALARM
            First time when level reaches full level a 10 second beep
              will sound if optional  alarm is connected to head2 output
              terminal (see wiring diagram)
            Time for alarm is adjustable on "alarm time" screen
                                                                                   ****STANDBY****
                                                                                ****STANDBY****
                                                                               MODE AUTOMATIC       TANK IS FULL
            Adjusting ALARM on time
            Time for  optional alarm can be adjusted between
            one to twenty seconds  as follow:
            • Change to MANUAL mode (see set mode section)
            • Scroll to "ALARM TIME" screen using < or> keys
            when unit is not in a cycle
            • Hold 'MODE' button until digits flash
            •  Use arrows keys (< >) to adjust time                             ****STANDBY****        ALARM TIME
            •  press 'MODE ' again to stop flashing                            MODE AUTOMATIC                  10
            • Change back to desired mode

            Adjusting Tranfer/Macerator pump On Time
            TheTranfer/Macerator pump on time is factory set to eight
            seconds. If the on time requires adjustment, follow steps
            below.
            • Change to MANUAL mode
            From the Electro Scan LCD Display                                   ****STANDBY****   TRANF PUMP TIME
            •   Scroll to "TRANF PUMP TIME" screen using  < and >              MODE AUTOMATIC
                                                                                        8
               keys when unit is not in a cycle.
            •   Hold ‘mode” button until digits flash.
            •   Use <or > keys to set on time in seconds for pump.
            •   Change back to desired mode.