WIRING   WARNING:  Hazard of Shock and Fire            Before  turning  on  power,  make  sure  that
                                WIRING
                                                                      treatment tank is full of salt water.
             •  Always use proper wire, wire connectors and
                 fuse/circuit breaker.  See Specification Chart.
             •  Secure wire properly.
             •  Do not connect other appliances to electro
                 scan circuit.
                                                                                Loosen Screws
                                                                                                          Knock
             •  Make sure power is off before proceeding.
                                                                                                          Outs
                                                                                Electro Scan
             •  Improper wiring can damage the Circuit
                 Board and void warranty.

             Treatment Unit                                                     Control Unit
             1.    Determine proper wire size from wire chart
                   on specifications page.                      START UP
             2.    Run  supply  wire  from  battery  NEG  to    1.    Start with empty  holding tank. If tank is not
                   Negative (NEG) terminal on Treatment tank.        empty , power up macerator motor to empty
             NOTE:Do not connect supply POS to treatment             tank.
                   tank, connect to control unit.                      To run macerator/tranfer pump only
             Control Box                                               1 Set the mode to MANUAL
             NOTE: Future access to control box is imperative.         2 Press start stop button to start sytem
                   If unit is installed in an area where access will          with pump
                   be difficult contact Raritan for instructions on        3 After macerator  pump stops, prees start/
                   mounting the control box for distance more                 stop again to to stop system
                   than two feet.                                      4  Repeat steps  2 &3 several times to
             1.    Run supply Positive (POS) to control unit                         empty tank
             2.    Fuse or circuit breaker must be installed
                   between source and electro scan on positive   2.    For  system used with  fresh water only:
                   wire.                                             Remove cross over cap from Electro Scan
             3.    Connect wiring harness between treatment          treatment tank  and add seawater salinity
                   tank and control box. Control box side is         salt water to the Electro Scan tretament tank.
                   marked with wire identification and colors.       Each gallon of water must contain 4 oz. by
             4.    Connect wiring harness from level sensor/         weight of salt for seawater salinity. or
                   macerator pump as per wiring diagram to I/O   3.    Turn on power, check the mode and change
                   board on the control unit. Connect Red wire w     if needed
                   /fuse  to positive terminal on the control unit.   4.    Use status panel start button to run one cycle
                   Feed wires thru   side holes (knockout) and       (MANUAL MODE)without error or warn-
                   connect to ext trig, man in, and Aux terminal     ings. If any error or warning refer to Electro
                   per color marked on    wiring diagram.            Scan manual troubleshooting section.
             System Status Panel                                     Note: if salt is not added in step 2 , unit will
             1.    Connect cable from System Status Panel to         give error for low amps for two or three
                   panel 1 jack on Control Unit.                     cycles before salt feed system feed enough
             2.    Secure cable strain relief.                       salt in the system.
             LCD Display                                        5.   Start using toilets.
             1.    Connect cable from LCD Display to display
                   jack on the Control Unit.
             2.    Secure cable strain relief.