Page 6 - Raritan Hold-N-Treat Electroscan EST System L372v0717
P. 6

Electro Scan System Status Panel
          INSTALLATION
             Mounting Electro Scan System Status Panel

             Note:
             As certified by USCG, Status panel must be installed
             to indicate proper operation of Hold N' Treat system.
             • Locate where system status lights can be observed.
             • Note: Cables supplied are 16 feet (5 m)

               1.  Drill 1 1/2" (38mm) hole for back of panel.
               2.  Route cable between panel and  Electro Scan
                   Control Unit.
               3.   Plug cable into back of panel.
               4.  Mount panel using 2 screws provided.

               Mounting Electro Scan System LCD Display


               Note:
             • Locate where display  can be read if needed.
             • Cables supplied are 16 feet (5 m)


               1.  Locate in an area where display can be read if
                   necessary.
               2.  Secure to wall with 2 screws.
               3.  Route cable between display and Electro Scan                    Not to scale
                   Control Unit.
                                                                         Electro Scan LCD Display
             PLUMBING:
             WARNING: HAZARD OF FLOODING
             •  Installations at or below waterline, at greatest
               angle of heel, MUST have a VENTED LOOP                          ****STANDBY****
               installed between Treatment Tank and Seacock/                  MODE AUTOMATIC
               Thru Hull Fitting. Install vented loops per
               manufacturer's instructions.
             •  Double  clamp  all  below  waterline  hose
               connections
             •  Do Not use metal fittings
                                                                                Plumbing Example
             NOTE:
             •  Use  PTFE  tape  or  nonpermanent  thread
             sealing compound on threaded PVC fittings and
             connections.
             • Avoid  low  areas  in  hose  that  would  allow
             untreated waste to collect.
             • Below Waterline Installations - An additional
             vented  loop  needs  to  be  installed  between
             Macerator Pump and Treatment Tank. Height of
             vented loop needs to be equal to or greater than
             the vented loop installed between treatment tank
             and thru hull fitting. Vented loop prevents cycling
             of macerator pump due to backflow.                                                         L372 0717jlc
                                                               6