Page 6 - Raritan Hold-N-Treat Electroscan EST System L372v0717
P. 6
Electro Scan System Status Panel
INSTALLATION
Mounting Electro Scan System Status Panel
Note:
As certified by USCG, Status panel must be installed
to indicate proper operation of Hold N' Treat system.
• Locate where system status lights can be observed.
• Note: Cables supplied are 16 feet (5 m)
1. Drill 1 1/2" (38mm) hole for back of panel.
2. Route cable between panel and Electro Scan
Control Unit.
3. Plug cable into back of panel.
4. Mount panel using 2 screws provided.
Mounting Electro Scan System LCD Display
Note:
• Locate where display can be read if needed.
• Cables supplied are 16 feet (5 m)
1. Locate in an area where display can be read if
necessary.
2. Secure to wall with 2 screws.
3. Route cable between display and Electro Scan Not to scale
Control Unit.
Electro Scan LCD Display
PLUMBING:
WARNING: HAZARD OF FLOODING
• Installations at or below waterline, at greatest
angle of heel, MUST have a VENTED LOOP ****STANDBY****
installed between Treatment Tank and Seacock/ MODE AUTOMATIC
Thru Hull Fitting. Install vented loops per
manufacturer's instructions.
• Double clamp all below waterline hose
connections
• Do Not use metal fittings
Plumbing Example
NOTE:
• Use PTFE tape or nonpermanent thread
sealing compound on threaded PVC fittings and
connections.
• Avoid low areas in hose that would allow
untreated waste to collect.
• Below Waterline Installations - An additional
vented loop needs to be installed between
Macerator Pump and Treatment Tank. Height of
vented loop needs to be equal to or greater than
the vented loop installed between treatment tank
and thru hull fitting. Vented loop prevents cycling
of macerator pump due to backflow. L372 0717jlc
6
6