Page 2 - Raritan Hold-N-Treat Electroscan EST System L372v0717
P. 2
OPERATION
Important
• Ensure the Electro Scan is operating properly.
Refer to the Electro Scan Manual for proper opera-
tion.
• Use of certain chemicals in toilet or holding tank
will cause damage to the Electro Scan. We rec-
ommend ONLY Raritan C.P. Cleans Potties and RED
Raritan K.O. Kills Odors. GREEN
• Select "NO DISCHARGE" mode to prevent acti-
vation of the ‘Hold n’ Treat when in No Discharge Flashing: Flashing:
Zones. Warning: See display Treatment process on
Solid:
TO SET MODE: Error: See display
There is a 5 second delay for changed mode to be
effective. Mode can only be set when unit is
not in a cycle.
Scroll to "MODE" screen using ">" key.
Use MODE key to toggle between AUTOMATIC, AUTOMATIC
MANUAL or NO DISCHARGE mode. PRS MODE TO CHG
Use "<" key to return to home screen or control will
reurn to home screen after few seconds.
Note : Default mode after powering up is mode
in which unit was last run. In case of loss of
power unit will go to back to mode it was run- PRESS TO PRESS TO SWITCH
ning. Units are shipped with nodischarge mode TOGGLE BETWEEN MODE TO THIS SCREEN
DISPLAY STATUS
AUTOMATIC MODE: ****STANDBY**** ****STANDBY****
Treatment starts when level is higher than the low level MODE AUTOMATICMODE AUTOMATIC
in the tank and continues till level is lower than low
level. Display indicates one of the following status
• Pretreatment or treatment cycle
Electroscan treatment cycle is running, see
electroscan manual for details on display
• Processing: between cycles
Treatment is between cycles, there is a 30
second wait before next cycle starts. Green LED will PROCESSING
BETWEEN CYCLE
flash on system status panel during this time
• Processing: cooldown cycle
Treatment has processed five cycle and
system is in cooldown cycle for 15 minutes. System
status green LED will flash during this time.
• Standby mode: tank is near empty
NOTE: If start/stop button is pressed to stop electroscan
treatment cycle , mode will change to MANUAL. PROCESSING
COOLDOWN CYCLE
2 L372 0717jlc
2