Page 2 - PHII - PHIIE Owners Manual L04v0320PHIIOM
P. 2
OPERATION
OPERATION\CLEANING
WARNING: DO NOT adjust valve handle (1209BW)
while toilet is operating.
1. With valve handle in the "FLUSH" position pumping Valve handle must be fully in the
the handle (or pressing the button on electric units) "FLUSH" or "DRY" position only.
will draw water in and discharge the bowl contents.
2. With valve handle in the "DRY" position pumping
the handle (or pressing the button) will only discharge
the bowl contents while drawing air in through the air
valve assembly to prevent a build-up of pressure.
• We reccomend single ply toilet paper.
• Water should appear in the bowl within ten seconds.
If not, see troubleshooting section. Position for intake
• Hard objects or stringy substances (paper towels, of water and
feminine hygiene products, filter cigarettes, etc.) must discharge of bowl
not be thrown into the toilet as they will cause damage. contents
• Always shut off seacock(s) before leaving the boat
unattended.
RETURNING PHEII TO MANUAL OPERATION
WARNING: Secure circuit breaker in "OFF" position
before proceeding.
1. Remove arm bolt and nut (#1115 and #1115A) from
the top of the connecting rod (#1116BW). Position for
2. Displace connecting rod (#1116BW) from track. discharge of bowl
3. Insert the handle (#1208W) and cotter pin (#1210A). contents only (no
To return to electrical operation, reverse procedure. water coming in)
Cleaning Instructions
IMPORTANT: Do not use cleaners that contain
ammonia, ethyl acetate, phosphoric acid or
concentrated chlorine bleach. These may cause
damage to the toilet.
Using C.P. a bio-enzymatic toilet bowl cleaner (available
from Raritan Engineering) will keep the bowl clean and
fresh smelling. Part # 1PCP32
Recommend Visual Inspection
For leaks at toilet and hose connections
Hose clamps
Condition of hoses C.P.
Seacocks
Condition of wires and connections
In-Line Strainer (if you have one)
Super Lube is a registered trademark of Synco Chemical Corp. 2 L04v0320jlc
®
2