SAFETY WARNING: HAZARD OF FLOODING - Always shut off seacock(s) before leaving the boat unattended.
IMPORTANT SAFETY INSTRUCTIONS:
Double clamp all below waterline hose fittings and check frequently for integrity.
Toilets mounted at or below the waterline must have
a vented loop installed in the discharge line. The top
of the vented loop must be a minimum of 4" (10cm)
above the waterline at the boats greatest angle of heel
(see vented loop manufacturer’s instructions).
Sea Water Models must also have a vented loop in-
stalled between the intake pump and the toilet bowl.
Double clamp all below waterline connections.
WARNING:
Young children should NOT be left unsupervised
around toilet. Serious injury or death could occur.
Children can drown in water retained in the bowl.
Seat and/or lid could close and strike child.
Always replace circuit breaker and fuses with same
rating . Use Raritan parts to maintain ignition pro-
tection requirements.
• No special toilet paper is required.
Cleaning Instructions • Water should appear in the bowl within
IMPORTANT: Do not use cleaners that contain ten seconds. If not, see troubleshooting
ammonia, ethyl acetate, phosphoric acid or section.
MAINTENANCE
concentrated chlorine bleach. These may cause • Hard objects or stringy substances (paper
damage to the toilet. towels, feminine hygiene products, filter
Using Raritan C.P. (part# 1PCP32) a bio-enzymatic cigarettes, etc.) must not be thrown into
toilet bowl cleaner will keep the bowl clean and fresh the toilet as they will cause damage.
smelling. • Always shut off seacock(s) before leaving
Recommend Visual Inspection the boat unattended.
P For leaks at toilet and hose connections Cleaning In-Line Strainer
P Hose clamps (Optional part# 163000)
P Condition of hoses (Sea Water Models only)
P Seacocks Shut off intake seacock. Unscrew bowl. Remove
P Condition of wires and connections filter. Clean bowl and filter with a clean cloth.
P In-Line Strainer (if you have one) Clean gasket and gasket contact surfaces
thoroughly. Replace gasket, filter and bowl. Open
seacock. Check for leaks.