Hold n’ Treat System



                                                      Model 21SR
                                     Installation and Maintenance Instructions
               THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED
                                  DURING BOTH INSTALLATION AND OPERATION
             WARNING:  Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
                         product. Equipment damage, injury to personnel or death could result from improper installation.
                         Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,
                         or injury or death to personnel that may result from Improper installation, trouble shooting, repairs
                         to or operation of this product.

             WARNING:  HAZARD OF SHOCK AND FIRE - Always use recommended fuse/circuit breaker and wire
                         size. The components are not  ignition protected and must not be installed in a gas engine room or
                         exposed to the possibility of spark.


            The ‘Hold n’ Treat System’ is designed to integrate   MODEL NUMBERS:
            both a Type I and Type III MSD (Marine Sanita-     21SR1512    Hold n Treat System with electro scan , 12 volt
            tion Device) to provide the user with a system that   21SR1524    Hold n Treat System with electro scan , 24 volt
            will be legal in all areas.   The Hold n' Treat Sys-  21R151201   Hold n Treat System without EST, 12 volt
            tem combines  Electro Scan (USCG Type I MSD)       21RS152401 Hold n Treat System without electro scan , 24 volt
            and a holding tank into one convenient system.
            All waste is stored in a 15 gallon holding tank with
            Electro Scan mode  determining how the waste
            is processed. This system eliminates the need for
            pump-out stations in most areas.

            OVERVIEW
            When Hold n’ Treat Electro Scan mode is set to
            AUTOMATIC the level of waste in the holding
            tank is monitored . Once the waste level is above
            low level the Electro Scan Control Unit activates a
            macerator pump which moves waste (approximate-
            ly 1 gallon) from the holding tank to the Electro
            Scan. This cycle is repeated continuously for five
            cycles. After the fifth cycle, the system enters a
            cool down cycle. It will remain in the cool down
            cycle for approximately fifteen minutes. After cool
            down, the process will resume until the waste in
            the tank drops below low level.
            When system mode is set to NO DISCHARGE ,           Operation in EPA designated "No Discharge
            processing is inactive and waste is collected in the   Zones" affects the MSD installation on every
            holding tank.                                       vessel that enters or stays in those waters. Flow-
            When mode is set to MANUAL, waste can be pro-       through devices are permitted if adequately
            cessed cycle by cycle by pressing Start/stop status   secured to prevent discharge of any sewage,
            panel.                                              treated or untreated.





             L372 0717jlc                                            1